Gohastings.com DAVC-4 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měření, testování a kontrola Gohastings.com DAVC-4. gohastings.com DAVC-4 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 17
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
INSTRUCTION MANUAL
TELEDYNE
HASTINGS
INSTRUMENTS
DIGITAL AVC
(DAVC-4, DAVC-5, DAVC-6)
ISO 9001
CERTIFIED
Zobrazit stránku 0
1 2 3 4 5 6 ... 16 17

Shrnutí obsahu

Strany 1 - HASTINGS

INSTRUCTION MANUAL TELEDYNE HASTINGS INSTRUMENTS DIGITAL AVC (DAVC-4, DAVC-5, DAVC-6) ISO 9001CERTIFIED

Strany 2 - Manual Print History

174-082010_Digital AVC Page 10 of 17 This signal is equal to an amplified tube millivolt signal. This signal will NOT be linearly proportional to t

Strany 3 - Table of Contents

174-082010_Digital AVC Page 11 of 17 Analog Output vs Pressure0.00010.0010.010.11101000 0.2 0.4 0.6 0.8 1 1.2VoltagePressure (Torr)DAVC6DAVC4DAVC4

Strany 4 - 1.0 General Information

174-082010_Digital AVC Page 12 of 17 3.3 Alarm Set point A single set point controls two open collector circuits. Though not the mechanical relays, t

Strany 5 - CE Standard Compliance

174-082010_Digital AVC Page 13 of 17 Character Description Valid Inputs: m Most Significant Digit Of Mantissa 1 - 9 d Decimal Digit

Strany 6

174-082010_Digital AVC Page 14 of 17 digit exponent before being accepted. There are no limit checks on the data; the user is free to choose any valu

Strany 7 - 2.0 Installation

174-082010_Digital AVC Page 15 of 17 3.6 Gauge Tube Operating Principle Operation of the Hastings gauge tube is based on a low voltage AC bridge that

Strany 8

174-082010_Digital AVC Page 16 of 17 B. Turn the HTR potentiometer on the top panel until the either the voltage measured between pins 6, Analog Sig

Strany 9 - 3.0 Vacuum Gauge Operation

174-082010_Digital AVC Page 17 of 17 4.1 Warranty Repair Policy Hastings Instruments warrants this product for a period of one year from the date of

Strany 10

174-082010_Digital AVC Page 2 of 17 Manual Print History The print history shown below lists the printing dates of all revisions and addenda created

Strany 11 - Analog Output vs Pressure

174-082010_Digital AVC Page 3 of 17 Table of Contents 1.0 GENERAL INFORMATION ...

Strany 12 - 3.4.1 Command Syntax

174-082010_Digital AVC Page 4 of 17 This manual contains technical and general information relating to the installation, operation, and calibration o

Strany 13

174-082010_Digital AVC Page 5 of 17 1.3 Compliance data 1.4 Safety The following symbols and terms may be found on THI products and/or in THI

Strany 14

174-082010_Digital AVC Page 6 of 17 1.4.3 Calibration Reference Tubes THI Reference Tubes employ the same metal thermopiles used in all THI Vacuum

Strany 15

174-082010_Digital AVC Page 7 of 17 2.1 Power-I/O Cable The Power-I/O Cable is assembled at the factory as shown in Fig. 1. Its terminal end is fin

Strany 16

174-082010_Digital AVC Page 8 of 17 Fig. 2 Relay Hook Up DIGITAL COMMONALARM 1 ALARM 2 DIGITAL COMMONDIGITAL COMMONPOWER COMM

Strany 17 - 4.0 Warranty

174-082010_Digital AVC Page 9 of 17 All THI gauge tubes are shipped with a protective cap or cover at the evacuation port to reduce contamination an

Komentáře k této Příručce